Using the Time Domain Reflectometer to Check for and Locate a Fault
M. Ramphal, E. Sadok (OH)
Development and Implementation of the Bruce B Secondary Side Flow Accelerated Corrosion Program
D.E. Stephenson (OH)
1B: Reliability Improvements - 1
RCM: The Bruce B Experience
E.S. Hill (NUS Corp, USA), E.K. Doyle (OH)
Darlington NGD Preventive Maintenance Enhancement Program
D.J. Phillips (OH)
1C: Emerging Issues
Bruce NGS A Unit 4 Preheater Divider Plate Failure
M. Langridge, D. Mclnnes (OH)
Relief Valve Failure on Pickering Unit 2
R. Goodman (OH)
1D: Steam Generator Monitoring and Strategy
Non-Intrusive Downcomer Flow Measurements: A Means of Monitoring Steam Generator Performance
C.E. Taylor, J.E. McGregor, C.A. Kittmer, M.J. Pettigrew (AECL), E.F. Jelinski, D.A. Seppala (OH)
Darlington Steam Generator Life Assurance Program
E. Jelinski, M. Dymarski, C. Maruska, E. Cartar (OH)
Corrosion-Product Inventory: The Bruce-B Secondary System
J.A. Sawicki (AECL), J. Price, M.E. Brett (OH)
1E: Tools and Instrumentation
Portable Radiation Instrumentation Traceability of Standards & Measurements
A. W~seman, M. Walke (OH)
The Role of a Certified Calibration Laboratory in a Station's Measuring and Test Equipment Calibration, Repair, and Documentation Program
K. Ebenstreit, N. Maclntosh (OH)
Portable Digital Electronic Radiography System
B. Sawicka (AECL)
2A: Improving Valve Performance
Air Operated Valve Maintenance at Bruce 'A'
K. McLeod (OH)
Implementation Challenges of a Motor Operated Valve Program
T.L. Ferguson (OH)
Darlington NGD Liquid Injection Shutdown System (LISS) Valve Performance
M. Wightman, F. Amantea, B. Speer, A. Rouhi (OH)
2B: Fuel Channel Inspection and Maintenance - 1
Fuel Channel Replacement Experience at Wolsong Unit 1
B.S. Han (KEPCO), M.M. Cobanoglu (AECL)
Removal of a Seized Fuel Channel from the Kanupp Reactor
W. Butt (KANUPP), R. Gunn (AECL)
Wet Scrape Sampling Campaign: Bruce 'B' Unit 6, Spring '95
S. Bennett (OH)
2C: Steam Generator Maintenance
Gentilly 2 Divider Plate Replacement
J. Forest (HQ), E. Kiisel, G. McClellan, W. Schneider (BWC)
Recent Developments in Plugging of Steam Generator Tubes
S. Buhay, R.C. Abucay (OH)
2D: Environmental Qualification
Maintenance and Environmental Qualification
R.S. Martin (United Energy Services Inc.), D.G. Austin (OH)
Environmental Qualification - Walkdowns: The Documentation of Configuration Information for Safety Related Components, Equipment and Systems
J. Melmer (OH)
Environmental Qualification Program for Wolsong Project
A. Duggal, H. Johal, F. Yee (AECL), S.K. Suh (KAERI)
1A:
2E: Predictive Maintenance - 2
Validation of the Dynamics of SDS and RRS Flux, Flow, Pressure and Temperature Signals Using Noise Analysis Techniques
0. Glockler, D.F. Cooke, M.V. Tulett (OH)
Portable System for Reactor Noise Data Acquisition
S.T. Craig, P.D. Tonner, J.P. Johnston, L.E. Nicholson (AECL), 0. Glockler, D. Williams (OH)
Flow-Accelerated Corrosion in Nuclear Power Plants: Application of Checworks at Darlington
C. Schefski, J. Pietralik (AECL), T. Dyke, M. Lewis (OH)
3A: Instrumentation and Control - 1
A Requirements Checklist for the Replacement of Analog Fischer and Porter Process Controllers with New Digital Models
A. Beauchamp (AECL)
Upgrading from the Dicon Wiring Management System to IntEC at the Gentilly 2 Station
P. Theoret (HQ)
Operating Experience in Engineering and Instrumentation & Control Areas Regarding a Candu 600 Refuelling System
E. Binetti et al, (Nucleoelectrica, Argentina)
3B: Fuel Channel Inspection and Maintenance - 2
Slarette Operations at Candu 6 Stations
D.J. Burnett (AECL)
Design of the Minislar System for Bruce A
M.G. Gray (GEC)
Fuel Channel Conditions Encountered During Slar and the Implications on Slar Strategies.
J. Gierlach, M. Furniss (OH), P. Gauthier (HQ), P. Ahearn (NBP)
3C: Steam Generator Cleaning
Water Lancing of Bruce-A Unit 3 and 4 Steam Generators
F. Puzzuoli, B. Murchie, S. Allen (OH)
Steam Generator Waterlancing at DNGS
D. Seppala (OH), E. Kiisel, F. Kamler (BWC), J. Malaugh (OH)
Steam Generator Secondary Side Chemical Cleaning at Point Lepreau using the Siemens High Temperature Process
K. Verma, C. MacNeil (NBP), S. Odar, K. Kuhnke (Siemens)
Pickering Unit 1 Chemical Cleaning
J.L. Smee (Niagara Technical Consultants), R.J. Fiola (BWC), K.R. Brennenstuhl, D.D. Zerkee, C.M. Daniel (OH)
3D: Predictive Maintenance - 3
Elastodynamic Spot Testing - Assessing Serviceability of Aging Elastomer Parts
0. Gracie, R. Metcalfe, R. Wensel (AECL)
Check Valve Diagnostic Program at Bruce A
S. Marsh (OH)
The Role of Lubricant Analysis in Maximizing Lubricant and Equipment Life
J. Janis (OH)
Condition Based Maintenance Pilot Projects at Pickering ND
R.T. Zemdegs, F.K. Fitzsimmons (OH)
3E: Decontamination and Radiation Protection
PND Fuel Handling Decontamination Program: Specialized Techniques and Results
R. Pan, K. Hobbs, M. Minnis, K. Graham (OH)
Decontamination and Recovery of Materials at Nuclear Facilities - Operating History
P.J. Gillis (Non-Destructive Cleaning Inc), J. Ackeroyd (J. Ackeroyd & Assoc)
Rehabilitation Activities and Radiation Protection Requirements in a Candu Facility
J.K. Mohindra, D. Papavramidis, I. Lake (OH)
4A: Instrumentation and Control - 2
Gentilly 2 Digital Control Computer Maintenance Strategy
P. Meloncon, J. Hubert, N. Gour (HQ)
Evaluation of Candu Safety-System Calibration Accuracy Through Monitoring
H.W. Hinds (AECL), R. MacKay (OH)
Point Lepreau NGS RTD Cable Assembly Failure & Replacement Program
M.P. Callister (NBP)
4B: Fuel Channel Program Optimization
Fuel Channel In-Service Inspection Programs - Program Design for Maximum Cost Effectiveness
N. van den Brekel (OH)
Fuel Channel Life Limiting Factors that Dictate Fuel Channel Maintenance Requirements
P.J. Richinson, H.W. Wong (AECL), P.J. Ellis (OH)
New Concepts, Requirements and Methods Concerning the Periodic Inspection of the Candu Fuel Channels
J.R. Denis (OH), M. Soare (INR)
4C: Inspection Techniques
Transmit-Receive Eddy Current Probes for Defect Detection and Sizing in Steam Generator Tubes
L.O. Obrutsky, T. Harasym, V.S. Cecco and S.P. Sullivan (AECL)
Eddy Current Technique for Detecting and Sizing Surface Cracks in Steel Components
V.S. Cecco, J.R. Carter, S.P. Sullivan (AECL)
4D: Reliability Improvements - 2
Primary Heat Transport Pump Mechanical Seal Replacement Strategy for Pickering B
V. Chacinski (OH)
Upgrading Primary Heat Transport Pump Seals
T. Graham, R. Metcalfe, D. Rhodes (AECL), D. Mclnnes (OH)
Inflatable Door Seals - Reduced Maintenance and Longer Service-Life
S. Kuran, R. Wensel (AECL), M. Lazic (OH)
4E: Maintenance Program Strategies - 1
The Development of a Station Maintenance Strategy
F. Fitzsimmons, R. Bearton, T. Andreeff (OH)
Atomic Energy Control Board (AECB) Staff Assessment and Views of Current Maintenance Practices at a Four Unit Candu Plant
I. Malek (AECB)
Peer Evaluation Experience with Maintenance Program Evaluation
F. Saunders, M. Gerard (OH)
5A: Valve Packing Experience
Control Valve Friction Operational Experience at Darlington NGD
B. Speer (OH)
Darlington NGD Valve Packing Program
C. Spence (OH)
BNGS B Valve Packing Program
D. Cumming (OH)
5B: Remote Tooling / Robotics
Mobile Robotics for Candu Reactor Maintenance: Case Studies and Near-Term Improvements
M.G. Lipsett (AECL), K.H. Rody (OH)
Ring Thermal Shield Piping Modification at Pickering Nuclear Generating Station 'A' Unit 1
R. Brown (OH), M.M. Cobanoglu (AECL)
ARK-2: A Mobile Robot that Navigates Autonomously in an Industrial Environment
N. Bains (AECL), S. Nickerson, D. Wilkes (OH)
5C: Fuel Handling
Underwater Fuel Handling Equipment Maintenance Verification of Design Assumptions, Specific Problems and Tools, Case Study
J. Kurek (OH)
Ultrasonic System for High-Accuracy Thickness Measurement of Fuel Bundie Bearing Pads and Shield Plug Crimps
P. Ciorau, B. Bevins, L. Gilham (OH)
Darlington NGD Fuel Handling Head Eight Acceptance Program
P.H. Skelton, T. Sie (OH), J. Pilgrim (GEC)
5D: Reliability Improvements - 3
Improved Reliability, Maintainability and Safety Through Elastomer Upgrading
R. Wensel, K.C. Wittich (AECL)
Status of the Reliability Centered Maintenance Program at Ontario Hydro's Bruce 'A' Nuclear Division
I. Khan (OH)
Information Management for Maintenance of Instrument Calibration Data
Y. Tam (OH)
5E: Maintenance Program Strategies - 2
Bruce Unit 2 Lay-Up Engineering Assessment
D. Iley (OH)
Effective Utilization of Maintenance Staff in Design and Implementation of Major Project Work
D. Wyman, J. Dingle, R. Brown (OH)
Current Experience in Supporting Commercial Nuclear Power Plant Maintenance
J.M. Jenco, K.F. Barry, W.E. Johnson, J.P. Sharkey, R.I. Wolfgang (Nuclear Maintenance Applications Center)
Miscellaneous
Research on Nondestructive Examination Methods for Candu Fuel Channel Inspection
M. Soare, F. Petriu, V. Toma, V. Revenco, A. Calinescu, R. Ciocan, C. Iordache, L. Popescu, M. Mihalache, C. Murgescu (INR)